WATERWORKS INTERNATIONAL

AUTOMATIC WATER FILTER SYSTEMS

Premier-Flo self-contained filter plants shall consist of the following major components: base, pump, motor, strainer, facepiping, valve, controls, and filter vessel. The system shall be shiped as a complete factory assembled and tested unit. Filter media shall be shiped with the unit for field installation.

COMPONENT SPECIFICATION
BASE Standard: High density black polyethylene
  Addition: Structural steel, primed and painted
  Addition: Type 304 stainless steel
     
PUMP Standard: Self-priming; close grain cast and machined brass volute, impeller, and pump-to-motor coupling; close coupled to a TEFC motor; and a capable of GPM at feet TDH.
     
MOTOR Standard: TEFC, heavy gauge rolled steel case; NEMA 56C frame; 1.15 service factor at 40°C over ambient;
HP; and at the following VAC and phase:
single phase 120V; 208V; 230V
three phase   208V; 230V; 460V
  Option: 575V three-phase.
     
STRAINER Standard: Basket type, FRP body, ABS basket, clear lexan cover, held in place by stainless steel band clamp
     
FACEPIPING Standard: Schedule 80 PVC; backwash sight glass; influent / effluent pressure gauges, 0-60 psi, liquid-filled
  Addition: Schedule 80 CPVC for system water temperatures of 120° to 180° F.
     
VALVE Standard: CPVC, 3-way, valves with 24 VAC electric actuation.
     
CONTROLS Standard (three phase or single phase, Automatic backwash operation) UL Listed control panel with: minimum NEMA 3R enclosure; motor starter with thermal overload and short circuit protection; transformer to convert supply to 24 VAC control power; through-the-door power disconnect; differential pressure switch; programmable relay with adjustable timing controls for backwash steps; 30-second time delay in delta P switch circuit, 1-100 hour "re-setting" timer for either/or backwash initiation; manual ON/OFF switch; and manual backwash initiation switch.
  Option: Backwash counter.
  Option: Fresh water backwash from municipal water supply.
  Option: Fresh water backwash from static water supply using pump to assist.
  Option: Integral backwash effluent regenerator for zero discharge.
  Addition: Backwash lockout between/among units, to prevent simultaneous backwash of multiple filter units; 0-15 minute adjustable lockout time delay relay.
  Addition: Contacts for connection to BMS, additional specifications required from owner.
  Addition: Contacts and HOA switch for remote start/stop.
  Addition: Overload pilot light.
  Option: Manual backwash; single-phase; three-phase.
     
VESSEL Standard: 18 gauge type 304 stainless steel; cycolac and styrene internals; 50 psi working pressure; fitted with tank drain, manual air relief valve, 35 psi automatic pressure relief valve. Maximum flow rate GPM at 20 GPM per square foot filter surface area.
     
MEDIA Standard: Quartzite or silica in nature, hard, not smooth, uniformity coefficient of 1.7, relative size of .45 to .55 mm, containing no more than 5% flat particles or more than 1% clay, loam dust, or toher foreign material. Media weighs 100 lbs per cubic foot.
     
NOTE Backwash flow rate, irrespective of water source, must be no less than 75% and no greater than 100% of the vessel's designed maximum gpm. Backwash duration is factory preset at 3 minutes and is field adjustable.